Manicure / single

Single manicure table: one station, specified properly.

One station is the cheapest way to test a room, and the easiest place to get the height wrong. The table, the seat and the lamp are one decision.

At a glanceSALON FURNITURE SUPPLY
1Station
Per projectTop size
2Extraction routes
Per drawingStorage

One station is a height decision

A single station is the cheapest way to test a room and the easiest place to get the working height wrong. The table, the technician's seat and the client's hand are one triangle, and the triangle decides comfort across a shift.

The table top carries the hand at a fixed height. The seat decides where the technician's forearm sits. If the two are bought separately without a number between them, the station ends up at the height of whichever arrived first.

Dust, light and reach

Dust extraction at the table is a small intake near the client's hand, usually ducted down a leg. A room extractor pulls that dust across the technician first, which is why the extra carcass work pays.

Task lighting and reach follow the same logic. A lamp on a stand lights the room; a lamp at the top lights the nail, and the useful specification is its reach and colour. The top then has to be deep enough for two hands, a lamp base and a client's forearm, and shallow enough that nobody leans all day.

What a single station does well

It fits a narrow room. It lets one technician work while a second client waits at the reception desk, which is how most small studios actually trade. And it is the station that can be moved when the room is rearranged, because it does not depend on a shared dust route.

Its weakness is throughput, and the response is to plan the room so a second station can be added without moving the first, which means leaving the wall run and the power drop in the right place from the start.

Spec sheet

A value that comes from your room or product list is marked as such.

Single station specification sheet
FieldThis buildWhat the value decides
Top lengthPer project, from the station layoutSets the reach to the client and the space for a lamp and a tray
Top depthPer projectTwo hands plus a lamp base; deeper than that and the technician leans
Working heightPer drawing, matched to the seatThe single dimension that decides comfort across a shift
Top materialSolid surface, laminate or timber, per finishSolid surface takes an unjointed edge, timber needs a sealed face for acetone
ExtractionTable level intake or room duct, per projectTable intake needs a route through the leg and a filter position
Task lightBuilt in, clamped or free standing, per projectA built in lamp needs a hole and a cable route drawn before the top is cut
StorageDrawer, open shelf or a trolley alongside, per drawingA drawer under the top is the reachable place for files and tips
Cable routeDown a leg to a floor outlet, or to a wall plateThe route decides whether the station can move later
Certification routeConfirmed at quotation, per destination marketThe file follows the model and the electrical accessory separately

The sheet is a summary, not a substitute for the drawing. Values that read per project are confirmed against your room before the order is placed.

Where a single station fits, and where it does not

It fits a studio under about thirty square metres, a room shared with a hair station, a home studio with a dedicated room, or a clinic that offers nails as a secondary service. It also fits the first month of a new business, when the chair count is a guess rather than a plan.

It does not fit a studio whose business model is volume: two technicians working the same hours on one station will queue, and the queue is visible from the door.

It also fails where no wall is long enough for a top and a client seat together, and the answer there is a shorter run, not a smaller chair.

How buyers customise a single station, and what each option changes

Each row is what the option moves for the order, not what it costs.

Top size
Changes the reach and the material yield. A top cut to the room uses less material than a standard top, and it removes the gap at the wall.
Extraction route
Changes the carcass and the floor work. A table intake needs a leg route and a filter bay, which is drawn before the top is cut.
Lamp type
Changes the top drilling and the cable route. A built in lamp is a drawing item; a clamped lamp is a purchase.
Storage
Changes the knee space and the packing. A drawer stack on the technician's side is the usual answer.
Finish
Changes the approval route. A laminate is a swatch; a timber top needs a seal sample and a batch match.
Seat pairing
Changes the height of everything above it. Specifying the seat with the table is the only way the two arrive matched.

What to confirm before you approve a single station sample

6 checks on the single station build before the order is approved.

  • The working height with the seat you intend to use, measured to the top surface rather than to the frame.
  • The client's hand position with the armrest or the edge, checked by the technician who will work there.
  • The extraction intake position and the filter access, since both are inside the carcass.
  • The lamp: where it mounts, which way it reaches and where its cable runs.
  • The top edge detail on the client side, because that is the edge a forearm rests against.
  • The cable route to the floor outlet and whether the station can be moved without rewiring.

Questions that come back before the order

Short answers to the questions that arrive with the first email.

Is a built in lamp better than a clamped one?

It looks better and it costs a drawing revision. A clamped lamp can be changed in a year; a built in one is decided with the top. Choose by how long the room will stay as it is.

How much dust does a table intake actually catch?

It catches the dust that leaves the hand, which is the fraction that matters to the client sitting opposite. The airborne fraction is a ventilation question.

Can the station be moved later?

Only if extraction and power were planned for it. A station ducted through the floor is fixed; one ducted to a wall plate moves with the wall.

Send the room, get a quoted single station.

The measurement, the working side and the destination market are enough to start. The reply names the build, the options and the documents you asked for.